A portable contamination monitor with thin plastic scintillation detector for highly sensitive measurement of α-, β- and γ- contamination.

  • The innovative detector technology with thin-layer plastic scintillator provides key benefits over gas-filled or gas flow proportional detectors. These include reduced operating expenses, i.e. consumable gas and high repair costs in the case of Xenon detectors.
  • α-, β- and γ-radiation can be measured using one detector. The measuring system automatically detects the presence of α-radiation. Simultaneous, selective measurement of α- and β-/γ-contaminations is possible.
  • User-friendly, menu-driven configuration.
  • Important measurement parameters are protected by pass code number.
  • Calibrated reference nuclide file with integrated auto calibration.
  • Lightweight.
  • Integrated storage of measurement data, software for readout and processing of measurement data.
  • Connection option for different external detectors, e.g. for dose rate measurement.
  • Automatic detector identification.
  • Fixed location operation with wall mount including of inductive charging, controlling of measurement time and switching between background measurement and contamination measurement.
Code Description
12BT-COMO170 CoMo 170 Contamination Monitor
12BT-COMO170AWM Active Wall Mount
12BT-COMO170FT Floor Trolley

Subject to technical change without notice.

Detector Type Thin-layer plastic scintillation detector with ZnS coating
Detector Size 170 cm²
Background α: approx. 0.1 cps
α/β: approx. 15 – 25 cps
Background Subtraction With adjustable background measurement time
Measurement Electronics μ-controller supported electronics
Keyboard Foil keyboard, 5 function keys
Alarm Separately adjustable for each nuclide, acoustic alarm
Result Display Either in cps or nuclide-specific in Bq or Bq/cm²
Nuclides 25 nuclides, preset calibration factors, user-specific nuclides may be added integrated auto calibration
Measurement Time Continuous, for stationary operation adjustable in seconds
Display Large-area, graphical LC display 128 x 64 pixels, with illumination, duration of illumination adjustable
Power Supply 2 batteries, AA Mignon or corresponding rechargeable batteries, (NiCd, NiMH), can be charged via charge unit, in stationary mode via wall station with inductive charge conservation
Temperature Range –10°C to 40°C, no condensation
special version up to –20°C
Dimensions 280 x 125 x 135 mm (L (with handle) x W x H)
Weight ca. 750 g (including batteries)
Housing Ergonomically shaped plastic housing
Interfaces Serial interface RS-232
Boost charge/line operated external detectors

Efficiencies for various radionulcides. Average values from measurements with 100 cm2 compound

C-14 approx. 14 %
F-18 approx. 18 %
P-32 approx. 25 %
S-35 approx. 12 %
CI-36 approx. 42 %
K-40 approx. 30 %
Co-57 approx. 7 %
Co-60 approx. 27 %
Sr-89 approx. 27 %
Sr-90/Y-90 (related to Sr-90) approx. 42 %
Tc-99m approx. 3 %
In-111 approx. 8 %
I-123 approx. 7 %
I-125 approx. 12 %
I-131 approx. 21 %
Cs-137 approx. 35 %
Au-198 approx. 23 %
Ti-204 approx. 43 %
Am-241 α approx. 22 %
P-238 α approx. 12 %
U-238 α approx. 26 %