The PET Dispensing Pot is designed for precise, manual dose dispensing, offering optimal radiation shielding of the vial during dose dispensing with a BriTec PET Syringe Shield, thereby reducing operator finger dose exposure. 

Total weight: 28kg.

Equipment Description

  • Rotating PET Pot to allow vial to be inserted for
    ease of drawing dose into shielded syringe.

  • Removable shielded syringe sleeves to allow
    you to choose the most appropriate syringe.

  • Removable vial sleeves to allow you to choose 
    the most appropriate vial.

A manual is included and is intended to provide the user with detailed instructions for the safe and proper operation of the BriTec PET Pot. It is essential that the user thoroughly reads and understands the contents of this manual to ensure correct and safe use of the equipment.

What you’ll receive with your PET pot:

  • PET Pot Stand
  • PET Pot Body
  • PET Pot Lid
  • PET Pot Cap
  • PET Pot Sleeve Holder
  • 1ml Syringe Sleeve For Product 1BT-511S01
  • 2/3ml Syringe Sleeve For Product 1BT-511S02/3
  • 5ml Syringe Sleeve For Product 1BT-511S05
  • 10ml Syringe Sleeve For Product 1BT-511S10
  • PET Pot Base
  • Various Vial Inserts
  • Spring For Vials
Code Description
8BT-PETPOT1 PET dispensing pot

The PET Pot comes with a range of standard vial inserts for use with most commonly used vials. Custom vial inserts can be made to order, we recommend that you send us a sample vial so that we can ensure that the vial insert best fits your needs.

Should you use a bleed needle to maintain an even pressure within the vial, we strongly advise that no additional air is injected into the vial as this may cause increased pressure within the vial resulting in backflow through the bleed needle. We recommend practicing on vials containing dyed water until you are comfortable and familiar with the system and its operation. Please use the guide below to help with this. If you have any questions about the product or procedure then please contact us using the details on the back page.

This product must be used behind a shielded barrier such as our 5BT-LVB30 PET Barrier.

Step 1

Place correct vial insert into the PET Pot, then insert vial you are using into the PET Pot.

Step 2

Place shielded lid onto PET Pot. Rotate lid anti-clockwise 45° until it locks into place.

Step 3

Fix syringe guider into place.

Step 4

Lock syringe guider onto PET pot.

Step 5

Pull out the locating pin on the left hand side of the stand. Rotate the PET Pot 45° towards you so you can view the bleed needle hole. Insert the bleed needle through the hole and into the vial. Carefully bend the bleed needle away. Rotate an additional 90°.

Step 6

Insert a syringe with a sheathed needle into the syringe shield.

Step 7

Place the syringe shield onto the syringe guider and slide upwards so that the needle goes through the center of the vial septum. Tighten the screws to hold the syringe shield in place. Withdraw the required dose.

Step 8

Loosen the 2 side screws and slide the syringe shield down the syringe guider. Re-sheath the needle.

Step 9

Place the PET Pot back into its upright position. Remove the syringe guider and replace with the shielded cap.